CEISA

The product is used on Diesel-electric locomotives replacing the GNME32GCXe32a generator-motor rotating group and provides 24Vdc and 72Vac. The second voltage feeds the primary winding of a transformer with several secondary windings for 24V, 30V, 110V and 220V.
Supply voltage: 140...180Vdc Output rated voltage: 24Vdc (23,7...24,7Vdc) Long time output current at 24Vdc: 5,5A Short-circuit current: 4A(3,6...4,4A) Output rated voltage: 72Vef(71...73Vef) Long time output current at 72Vef: 30Aef Output voltage rated frequency: 50Hz Protection degree: IP20 Net weight: 29kg.